The MTM500E flush-mounted module is a wired electronic staircase lights timer, which allows the management of lights to be timed up to a maximum of 500W.
It includes double timings: the main one from 2 seconds to 4 hours and the prolonged one (1 hour), with switch-off warning.
it is possible to centralize the management of several MTR500Es via the pilot wire, using the CVI50 accessory (code 5454805).
Thanks to the “soft start / soft stop” function, it limits the inrush current during the lighting phase of the light circuit, thus increasing the life of the lamp and the buttons.
The module provides 2 types of integrated electronic protections: in case of short circuit on the load (with automatic reset after elimination of the fault) and against overheating. it is immune to mains disturbances up to 1.5 kV and 100% waterproof, therefore it can also be installed outdoors.
It also allows control via a low voltage button (12 or 48 V), both in direct and alternating, with the addition of the ADBT accessory.
Accessories:
ADBT (code 5454076): 12-48V AC or DC low voltage adapter
D600V (code 5454072): Diode for centralizing the modules via pilot wire
BV40 (code 5454071): Electronic coil. Allows the use of modules of the 500 range with pushbuttons with indicator light
CVI50 (code 5454805): Allows centralization of modules of the 500 range
Read moreProduct Booklets
INSTALLATION MANUAL - it,en,fr,es,de,nl,da
DS1054-042C • pdf 1.44 MB • ID: 609488
Declarations and certifications
Declaration of Conformity
CE_01980 • pdf 231.30 KB • ID: 588225
✦
Packaging quantity single: 1
✦
EAN single: 3760054540514
✦
Base: 45 mm
✦
Height: 75 mm
✦